HISTORICAL 10 · CASE #9

PASS

Pasmatic MSW 450/CW

Last verified: 20 Sept 2026

The blind run independently traced all three Rockwell migration families used in the real project.

Result

Machine / component
Pasmatic packaging machine / Rockwell legacy hardware
Problem class
Multi-family automation supersession
Blind conclusion
Locked before revealUse OEM migration paths per hardware family: PowerFlex 40/40P -> PowerFlex 525; Kinetix 6000 -> Kinetix 5700 as a coordinated servo-system migration; legacy MSR/Minotaur -> catalog/function-matched current safety solution. Preserve PLC/HMI behavior through controlled code changes and validation.
Historical result
The real modernization replaced nine MSR/Minotaur safety relays with GSR relays, three PowerFlex 40 drives with PowerFlex 525, and four Kinetix 6000 servo-system components with Kinetix 5700. PLC/HMI code was adapted and the work included safety documentation and validation.
2026 recommendation
The same migration families remain appropriate, but every item must be mapped by exact catalog/function. Safety migration requires functional validation; Kinetix is a system migration, not a drop-in component swap.
Verdict
PASS
Evidence quality
A

How the case was solved

This was the strongest multi-family test: the blind result independently identified all three migration families and the need for code and safety revalidation before the historical project was revealed.